EWRB, electrical safety and standards

A rooftop solar PV array.
A rooftop solar PV array.
A rooftop solar PV array. Photo: Forest355, Wikimedia Commons, CC BY-SA 4.0.

Electrical work in New Zealand is regulated.

Pluggered Ltd does residential, commercial and industrial electrical work, heat pumps, EV chargers, and EWOF and inspections. It also runs an online store that sells solar and battery gear. We do not install solar or batteries. See our services page.

Who the EWRB is

The Electrical Workers Registration Board was set up under section 148 of the Electricity Act 1992. Its job is to help keep people safe by making sure electrical workers are competent. It sets registration classes and limits of work, issues practising licences, runs the two-yearly competence programme, and deals with complaints and discipline. The Board has seven members, appointed by the Minister for Building and Construction. Five are registered electrical workers and two are lay members. You can check a worker on the EWRB public register.

How the safety rules work

The Electricity Act 1992 covers prescribed electrical work (PEW), registration and licensing, and the EWRB. MBIE administers the Act. The Electricity (Safety) Regulations 2010 set the detailed safety rules, including when work must be tested, certified and inspected, and which official standards apply.

Recent changes

A new EWRB registration framework began on 1 September 2024. It introduced endorsed registration classes for higher-risk work and for supervising more than two people at once. The endorsed areas are mining operations, medical cardiac protected areas, hazardous areas, mains parallel generation systems, and supervision of more than two people at one time. Electrical inspectors can supervise any number of people without the supervision endorsement, but they still need the relevant endorsement for the other endorsed areas. For electricians and some related classes, the endorsement must be held before the next practising-licence renewal on or after 1 September 2026, if they do PEW in an endorsed area. That rule already applied earlier to inspectors.

The Electricity (Safety) Amendment Regulations 2025 came into force on 13 November 2025 and updated the official standards cited in the Safety Regulations. From 13 November 2026, after a one-year transition, the newer cited standards apply to new work. Existing and in-process work may continue under the old rules if it is not electrically unsafe. The amendment also changed the allowed voltage at the point of supply to standard low voltage plus or minus 10%. The 2025 amendment had switched off part of the Wiring Rules about combined protective-earth and neutral (PEN) conductors. The Electricity (Safety) Amendment Regulations 2026 came into force on 2 October 2026 and restored that prohibition.

The standards that apply

AS/NZS 3000:2018, including Amendments 1, 2 and 3, is the Wiring Rules. It is the main installation standard for low and extra-low voltage work, and is cited in the Safety Regulations with New Zealand modifications in Schedule 2. AS/NZS 3008 is the cable-selection standard, with a New Zealand-conditions part (AS/NZS 3008.1.2). It is not cited by name in the Safety Regulations. AS/NZS 3019:2022 is cited in Schedule 2 for periodic assessment of electrical installations.

EV charging installations must comply with AS/NZS 3000 and the Safety Regulations. Schedule 4 cites IEC standards for the equipment, including IEC 61851-1 and IEC 62196-1. Pluggered supplies and installs home EV charging equipment.

For solar PV, AS/NZS 5033:2021 and AS/NZS 4777.1:2024 are cited in Schedule 2. AS/NZS 4777.2:2020, including Amendment 1, is cited in Schedule 4. All PEW that involves installing a PV system is high-risk and must be independently inspected. Not every solar job is a mains parallel generation system. AS/NZS 5139:2019 is the joint standard for battery energy storage systems. It is not listed by name in Schedule 2 of the Safety Regulations.

The store sells solar panels, solar inverters and home batteries. We do not install solar or batteries.

What is coming

In July 2026 the EWRB gave the Minister its latest five-year review of the occupational regulation parts of the Electricity Act. The Board said a comprehensive review is overdue. Those recommendations have not, by themselves, changed the Act. A bill before Parliament would amend several licensing regimes, including the Electricity Act 1992. It had its second reading on 30 July 2026. As at 22 November 2026 it had not had its third reading or Royal Assent, so it is not yet in force.

Electrical inspectors

Some electrical work must be independently inspected, on top of the testing and certification done by the person who carried out the work. High-risk PEW includes installing a photovoltaic system or a mains parallel generation system, mains work, and other work listed in the Safety Regulations. High-risk PEW must be inspected. A person must not inspect work that they carried out, supervised, or issued the certificate of compliance for. In the EWRB system, the authorised person is a licensed electrical inspector, working within their registration and any needed endorsement. After the inspection, they must issue a record of inspection.

Inspectors may also issue warrants of electrical fitness (an EWOF) for connectable installations such as campervans and caravans. A typical warrant lasts four years. If the work is on a mains parallel generation system, the inspector needs the Electrical Inspector (Endorsed Mains Parallel Generation Systems) class when the endorsement rules apply. For inspectors, those rules have applied since their first licence renewal on or after 1 September 2024. Electricians and electrical engineers who carry out that PEW need their own endorsed class.

Pluggered offers electrical inspections and campervan and caravan EWOF.

Micro-credentials

A micro-credential is a short, formal training product. It can help show knowledge and skill, but it does not replace EWRB registration or a practising licence. The EWRB has approved two Level 4 micro-credentials for the mains parallel generation systems endorsed classes: Grid-connected PV Systems, Design and Install, and Grid-connected Battery Storage Systems, Design and Install. Work experience can be used instead. For the Electrician (Endorsed Supervision) class, the EWRB names the Supervision of Prescribed Electrical Work micro-credential as one option.

To talk to Pluggered about electrical work, an inspection or an EWOF, use the contact page.

Sources